The Harshaw TLD Model 8800 Plus Automatic Card Reader is controlled through screen dialogues, using the mouse to make selections from the drop-down menus. It can also be networked with Thermo Scientific™ Harshaw TLD™ Model 4500 Manual Reader and Thermo Scientific™ Harshaw TLD™ Model 6600 Plus Automated Reader in discrete or shared dosimetry applications.
Description | Model 8800 Plus with EXT-RAD Option |
Detector Type | Photomultiplier Tube |
Dosimeter Reusability | <10% sensitivity change for 500 readouts (50 for EXT-RAD and DXT-RAD) |
Dynamic Range | 7 decades |
Product Type | Radiation Dosimeter Reader |
Sensitivity | <10% sensitivity change for 500 readouts (50 for EXT-RAD and DXT-RAD) |
Time and Temperature Profiles | Preheat temperature, 20°C to 200°C; Preheat time, 0 to 300 sec.; Acquisition time, 10 to 300 sec.; Linear temperature ramp, 1 to 50° per sec.; Acquisition temperature, to 300°C (option available to provide up to 400°C); Post-read anneal temperature, to 300°C (option available to provide up to 400°C); TTP Reproducibility, ±1°C |
Batch Uniformity | ±30% maximum deviation from the batch mean without application of element correction coefficients |
Capacity | Up to 1400 TLD cards including calibration cards, Seven 200-card capacity cartridges |
Card ID | Codabar barcodes: interlaced 2 of 5, code 39 |
Dark Current | <1μGy 137Cs equivalent dark current |
Heating Method | Contactless heated N2 |
Linearity | Less than 1% deviation |
Radiation Type | Beta, Gamma, X-ray, Neutron |
Reference Light | <1%High-voltage short-term stability, ±0.005% |
Repeatability | <2% variation based on one standard deviation for |
Stability | Based on one standard deviation of 10 consecutive |
Throughput | TLD cards, 140 per hr.; chipstrates, 140 per hr.; DXT-RAD 140 single element dosimeters per hr. |
Warm Up Time | <20 min. |
Weight | 180 kg |
Model 8800 Plus
Standard version, reads Harshaw TLD whole body, neutron and environmental TLD cards and extremity dosimeters on carrier cards. Includes reader, heating system, load and unload cartridges, card transport system, and single barcode reader. Thermo Scientific™ WinREMS™ Software runs on a separate external PC.
Model 8800 Plus EXT
Same as standard model, but includes a triple-head laser barcode scanner for reading EXT-RAD extremity chipstrates.
Model 8800 Plus DXT
Same as standard model, but includes a CCD camera for reading DXT-RAD extremity ringlets, EXT-RAD chipstrates and other standard Harshaw TLD cards.
Note: No annealing required; anneal part of the heat cycle can be used to remove residual signal after exposure to a high dose.